COMBUSTION GAS ANALYSER
For continuous measurement of oxygen and/or combustibles (COe) and enable increased combustion efficiency
• Unique close coupled, low extracted volume design protects sensors and provides fast, in-phase O2 and COe measurement without probe blockages
• Long life, low drift zirconia and catalytic sensors
• Protective, BASEEFA tested flametraps as standard
• Wide variety of probes and flanges
• Configurations for safe or hazardous area use
• Proven applications include power generation boilers, process heaters, thermal crackers and incinerators
SPECIFICATION | | |
GASES MEASURED | Oxygen (O2) | Combustibles (COe - Carbon Monoxide Equivalent) |
TECHNOLOGY | Zirconium oxid (zirconia) | Patented thick film catalytic sensor |
Typical fuels | All | <2.5% sulphur gas, oil and coal 1 |
PERFORMANCE f | | |
Min. recommended range: Max. COe in stream: | 0-1% O2 Not applicable | 0-500ppm 6000ppm |
Intrinsic error (accuracy): Recommended resolution: Sensor head response time (T90): Typical calibration period: | ±1% of reading or ±0.1% O2* 0.01% O2 <10 seconds 12 months | ±25ppm or ±5% of reading* 1ppm <20 seconds 2 months |
SIGNAL INPUTS/OUTPUTS | | |
Analogue Outputs: One configurable isolated 0/4-20mA per measurement (impedance 600
Ω or less)
O2 output configurable from 0-1% min. to 0-25% max. O2 in 1% steps
COe output configurable from 0-500ppm to 0-15,000ppm (measurement range remains as above)
Alarms & Relays: Four SPCO relays (250V ac/3A or 28V dc/1A max), configurable for Concentration Alarms, Faults, In Calibration, In Blowback, and solenoid valves for blowback and autocalibration
Digital Inputs: Two non-isolated digital inputs provided to initiate autocalibration and
perform blowback
PHYSICAL
Ingress Protection: IP66/NEMA 4X
Weight: Control Unit: <11kg (<24.3lbs) Sensor Head, dual transducer: <17kg
(<37.5lbs)
Mounting: Wall mounting sensor head, and wall mount 19” rack or panel mount
control unit, with a wide choice of probes,mounting flanges and
adaptors to assist retrofitting. See over for dimensions and more details
ENVIRONMENTAL
Area classification: Versions available for safe and hazardous areas (see over for details)
Ambient temperature: Sensor head -20°C to +70°C (-4°F to +158°F)
Control unit -10°C to +55°C (+14°F to +131°F)
Altitude: Maximum 2000m (6500ft) 1 Consult Servomex for high sulphur (> 2.5%) and other applications
***********************************************************************************************************************
Blog: Máy phân tích khí -----||----- Gas Analyzer
***********************************************************************************************************************