The DF-760E Nano Trace moisture analyzer is a combination Coulometric & Tuneable Laser
Diode sensor based analyzer, designed to measure trace oxygen and moisture as a contaminant in Ultra High Purity electronic grade gas for quality control.
FEATURES
Highly stable tuneable laser diode sensor for moisture measurement
Non-depleting sensor with 5 year sensor warranty for oxygen measurements
Minimal maintenance
Suitable for multiple background gases with a single unit
APPLICATIONS
Integrated Circuit Board Fabs
Leak detection
SPECIFICATIONS | |||
Gas Type: | O2 | Moisture | |
TECHNOLOGY | Coulometric non depleting electrochemical sensor | Tuneable Laser Diode | |
PERFORMANCE | |||
Maximum operating ranges: | 0-20ppm | 0-20ppm | |
Smallest recommended output range: | 0-1ppb | 0-2ppb | |
Intrinsic error (accuracy): | +/- 3% of reading or +/- 0.1ppb (whichever is greater) | +/- 3% of reading or +/- 0.2ppb (whichever is greater) | |
Response time (T90): | <15 seconds | <3 minutes at 1 liter/min | |
Zero drift/month: | Negligible | Negligible | |
Span drift/month: | Negligible | Negligible | |
Lower detection Limit (LDL): | 75ppt | 200ppt | |
Upset recovery time: | <5 minutes to return to within 10ppb of previous stable reading | <5 minutes to return to within 10ppb of previous stable reading | |
OUTPUTS/INPUTS | |||
Output: | Isolated 4-20mA dc, for both moisture and oxygen, 0-1, 0-2, 0-5, or 0-10 VDC for both moisture and oxygen (analog output can be configured to freeze during calibration) | ||
Output range: | Scaleable to any range between 0-2ppb to 0-20ppm | ||
Audible/visual alarms: | 4 oxygen levels, 4 moisture levels, temperature, electrolyte condition, moisture sensor diagnostic, loss of flow, zero verification, or calibration in process, moisture analyzer off-line, oxygen analog output freeze control during calibration | ||
Dual scale range: | Two user selectable secondary analog output ranges for rescaling the output once the primary range is exceeded | ||
Relay contacts: | 4 non-latching, independently assignable to oxygen alarms or oxygen calibration-in-process indicator, and 4 non-latching, independently assignable to moisture alarms. SPDT contacts rated for 5 amps at 30V dc. Up to 4 non-latching, independently assignable to alarms or indicators. SPDT contacts rated for 1amp at 30V dc. | ||
Serial communications: | Factory configured RS232 or RS 485 two-way serial communications | ||
Gas scale factor: | Background gas compensation for gases other than N2 | ||
Gas delivery system: | Pneumatically actuated springless diaphragm valves, orbital butt welded assembly with zero dead volume for sensor isolation and zero verification. High capacity purifier provides moisture and oxygen-free zero (not compatible on oxygen samples). Heated and temperature controlled sample delivery system. Integral pressure regulator with minimal wetted area. Bypass loop with flow control. 1⁄4” VCR inlet fittings, 1⁄4” compression bypass outlet fitting, 1⁄4” compression outlet fitting to vacuum source, 1⁄8” compression fitting for pneumatic gas inlet | ||
Aspirator vacuum source: | Aspirator with ¼” compression inlet and outlet fittings | ||
Mounting: | 19” rack mount NEMA 1 enclosure | ||
OPTIONS | |||
Pump vacuum source: | Pump with ¼” compression inlet and outlet fittings | ||
Hydrogen safety system purge: | Optional safety system for use with hydrogen includes Sample Delivery Interlock and Case Purge Valves for instrument housing, NEMA 4 enclosure and Z purge protection system for optional external vacuum pump. Hydrogen safety system can be ordered with or without the NEMA 4 enclosure and Z purge protection system for the optional vacuum pump (NOTE: hydrogen safety system limits available relays from 4 to 3) | ||
SAMPLE GAS | |||
Temperature: | 50°F to 176°F (10°C to 80°C ) Recommended heated sample line to 140°F (60°C) | ||
Dewpoint: | 9°F (5°C) below minimum ambient | ||
Condition: | Oil free, non-corrosive, non-condensing | ||
Particulates: | Filtered to 2µm | ||
Vent pressure: | Vent to atmosphere. | ||
Sample flow: | 2 to 5 l/min (For nitrogen only ) - contact Servomex for other background gases | ||
Bypass flow: | 0.25 to 2.5l/min | ||
Sample pressure: | 30 to 150psig (3.08 to 11.3 BarA) |
For samples containing acidic components contact Servomex for sample preconditioning options.
***********************************************************************************************************************